XFP Range

2016.01.05 · 海工灯具

首页 > 海工灯具 > 正文

XFP Range

XFP Range
Tubular Fluorescent Fitting with automatic switch off. 
DTS
 
 

Technical Data

Material End caps and cover in marine grade aluminium alloy type AS10GY30.Yellow polyurethane paint RAL 1003 (other colour on request)
-Offshore option 3 coats of paint.Extruded 2.5mm LEXAN 2034 polycarbonate tube, anti-UV protected. 7mm borosilicate glass tube. Neoprene gasket. Stainless steel screws
Rated voltages  
-Standard 230V 50Hz ferromagnetic ballast.
-Options 240V 50Hz -110V 50Hz-220V 60Hz-127V 60 Hz-110V 60Hz.
-Single/dual tube electronic ballast AC 220V to 240V-50 to 60Hz. DC 220-240V
Lamps (supplied on request) T8 bi-pin G13 tubes, Ø26 – white industry 4000°K (other colour temperatures on request). G11 compact fluorescent PL lamp.
Temperature Ambient temperature range -20°C to +55°C.Surface temperature classification T6
Protection class I   Automatic switch off on opening.
Terminal block Up 10mm2 (rigid wire), 4mm2 (flexible wire). Terminals supplied for L, N and PE, looping possible.
Fixing  
-Standard 2 chromed zinc articulated brackets (typeD023) for ceiling mounting
-Options 2 stainless steel brackets 304L (type D024) for ceiling mounting, 2 U-bolts and brackets in zinc chromed steel for pole mounting 1 1/4” (type D025), 1 1/2” (Type D026), 2” (type D027) 2 U-bolts and brackets in stainless steel 304L for pole mounting 1 1/4” (type D028), 1 1/2” (Type D029), 2” (type D030)
Other options Stainless steel canopy 304L, Stainless steel shockproof kit 304L (factory fitted)
Standard cable entries One M20 nickel chromed brass cable gland with fixing flange, Ø8-13mm.                               
-Option M20 metal cable gland for armoured cable type PEP.
Ingress protection IP 66/67 (EN60529)
Power factor 0.75 with ferromagnetic ballast (with capacitor exept 20W;0.60) 0.98 with electronic ballast
Shock resistance IK09 10 Joules (polycarbonate tube)
For use in Zone Zone 1, Zone 2
Glow wire test 960°C
 

Applications

  • Marine decklight
  • Refineries
  • Petrochem/chemical
  • Painting/solvent areas
 

Features

  • Automatic switch off on opening
  • Two body choices: 
     – Polycarbonate (lightness and shock resistance)
     – Glass (hostile environments)
  • Fast connection (EExe junction box)
  • Very low maintenance cost (standard components)
  • Total anti-corrosion and marine protection
 

Certificates

Certification standard:
CENELEC EN 50014, 50018, 50019
Ec type examination certificate:
Under the new directive 94/9/EC: LCIE 02 ATEX6171X

 