XEL/BAES Range

2016.01.05 · 海工灯具

首页 > 海工灯具 > 正文

XEL/BAES Range

XEL/BAES Range
Self-Contained Emergency Lighting.
DTS
 
 

Technical Data

Material End caps and cover in marine grade aluminium alloy type AS10GY30.Yellow polyurethane paint RAL 1003 (other colour on request)
 -Offshore option 3 coats of paint.Extruded 2.5mm LEXAN 2034 polycarbonate tube, anti-UV protected.7mm borosilicate glass tube. Neoprene gasket. Stainless steel screws      
Rated voltages and emergeny function Electronic ballast 230V 50-Hz. Remote control function.
-XEL 80 Ni-Cd battery, 3.6V 1.5Ah. Lumen output for 1 hour=60 lumen. Rated batttery duration=1 hour.
-XEL 300 Ni-Cd battery, 3.6V 4Ah. Lumen output for 1 hour=240 lumen. Rated battery duration=1 hour.
Lamp (supplied fitted)
 -XEL 80 Emergency lamp; 1x6W tube with G5 lampholder. Indicator lamp; 1 lamp 6.5V/0.15A with E10 lampholder.
 -XEL 300 Emergency lamp; 1x8W tube with G5 lampholder. Indicator lamp; 1 lamp 12V/2.2W with E10 lampholder.
Temperature Ambient temperature range; -5°C to +30°C. Surface temperature classification; T6 (gas), T6 85°C (dust)
Protection class I   
Terminal block Standard unswitched enclosure with battery switch off; as XEL. Enclosure with combined switch off. as XEP.     
Fixing  
 -Standard 2 chromed zinc articulated brackets (typeD023) for ceiling mounting
 -Options 2 stainless steel brackets 304L (type D024) for ceiling mounting 2 U-bolts and brackets in stainless steel for pole mounting 1 1/4” (type D025), 1 1/2” (Type D026), 2” (type D027). 2 U-bolts and brackets in stainless steel 304L for pole mounting 1 1/4” (type D028), 1 1/2” (Type D029), 2” (type D030)
Other options Stainless steel shockproof kit 304L (factory fitted)
Standard cable entries Unswitched enclosure with battery switch off; as XEL. Enclosure with combined switch off; as XEP.
Ingress protection IP 66/67 (EN60529)
Power factor Superior to 0.98
Shock resistance IK08 5 Joules (polycarbonate tube)
For use in Zone Zone 1, Zone 2
Glow wire test 960°C
 

Applications

  • Marine decklight
  • Refineries
  • Petrochemical/chemical
  • Painting/solvent areas
  • Pharmaceutical
  • Gas and Dust Areas
 

Features

  • Models available: “escape route lighting” and “large area” lighting
  • Fluorescent technology ensures improved lumen output and reduced maintenance
  • Self contained luminaires with built in automatic facilities (local indication of the result of tests or centrally monitored)
  • 3 body variations to simplify installation and maintenance (unswitched, with battery switch off, with battery and power supply switch off)
  • Two choices of tube: polycarbonate or glass
 

Certificates

Certification standard:
CENELEC EN 50014, 50018, 50019, 60598.2.22;NFC 71800, 71801
Ec type examination certificate:
Under the new directive 94/9/EC: 
LCIE 02 ATEX6170X (unswitched/with battery switch off), 
LCIE 02 ATEX 6171X (with battery and power supply switch off)
 